APU Pulse

From NESdev Wiki
Revision as of 05:25, 7 January 2017 by Tepples (talk | contribs) (Period divider is not reset on 4003/4007 write)
Jump to navigationJump to search

Each of the two NES APU pulse (square) wave channels generate a pulse wave with variable duty.

Each pulse channel contains the following: envelope generator, sweep unit, timer, 8-step sequencer, length counter. Note: the addresses below are write-only!

                     Sweep -----> Timer
                       |            |
                       |            |
                       |            v 
                       |        Sequencer   Length Counter
                       |            |             |
                       |            |             |
                       v            v             v
    Envelope -------> Gate -----> Gate -------> Gate --->(to mixer)
Address Bitfield Description
$4000 DDlc.vvvv Pulse 1 Duty cycle, length counter halt, constant volume/envelope flag, and volume/envelope divider period
$4004 DDlc.vvvv Pulse 2 Duty cycle, length counter halt, constant volume/envelope flag, and volume/envelope divider period
Side effects The duty cycle is changed (see table below), but the sequencer's current position isn't affected.
 
$4001 EPPP.NSSS See APU Sweep
$4005 EPPP.NSSS See APU Sweep
 
$4002 LLLL.LLLL Pulse 1 timer Low 8 bits
$4006 LLLL.LLLL Pulse 2 timer Low 8 bits
 
$4003 llll.lHHH Pulse 1 length counter load and timer High 3 bits
$4007 llll.lHHH Pulse 2 length counter load and timer High 3 bits
Side effects The sequencer is immediately restarted at the first value of the current sequence. The envelope is also restarted. The period divider is not reset.[1]

Duty Cycle Sequences

Duty Waveform sequence
0 0 1 0 0 0 0 0 0 (12.5%)
1 0 1 1 0 0 0 0 0 (25%)
2 0 1 1 1 1 0 0 0 (50%)
3 1 0 0 1 1 1 1 1 (25% negated)
The reason for these odd sequences is that the sequence counter is initialized to zero but counts downward rather than upward

The sequencer is clocked by an 11-bit timer. Given the timer value t = HHHLLLLLLLL formed by timer high and timer low, this timer is updated every APU cycle (i.e., every second CPU cycle), and counts t, t-1, ..., 0, t, t-1, ..., clocking the waveform generator when it goes from 0 to t. Since the period of the timer is t+1 APU cycles and the sequencer has 8 steps, the period of the waveform is 8*(t+1) APU cycles, or equivalently 16*(t+1) CPU cycles.

Hence

  • fpulse = fCPU/(16*(t+1)) (where fCPU is 1.789773 MHz for NTSC, 1.662607 MHz for PAL, and 1.773448 MHz for Dendy)
  • t = fCPU/(16*fpulse) - 1

A period of t < 8, either set explicitly or via a sweep period update, silences the corresponding pulse channel. The highest frequency a pulse channel can output is hence about 12.4 kHz for NTSC. (TODO: PAL behavior?)

The mixer receives the current envelope volume except when

  • The sequencer output is zero, or
  • overflow from the sweep unit's adder is silencing the channel, or
  • the length counter is zero, or
  • the timer has a value less than eight.

The behavior of the two pulse channels differs only in the effect of the negate mode of their sweep units.

Notice that a few Famiclone units have swapped APU duty cycles, as 12.5, 50, 25 and 25 negated instead.