User:Lidnariq/DPCM mistuning: Difference between revisions

From NESdev Wiki
Jump to navigationJump to search
(blah blah perfectly in tune with self fictional universe)
(provide intervals)
Line 84: Line 84:


In a fictional alternate universe, where the DPCM period tables had been chosen to maximize in-tune choices, perhaps the periods would have instead been some subset of the following rates:
In a fictional alternate universe, where the DPCM period tables had been chosen to maximize in-tune choices, perhaps the periods would have instead been some subset of the following rates:
: 48, 54, 64, 68, 72, 76, 96, 102, 108, 114, 128, 136, 144, 152, 162, 192, 204, 216, 228, 242 , 256, 272, 288, 304, 322, 342, 362, 384, 406, 432, 456, 484
{| class="wikitable"
All of these are within 6 cents of an exact number of semitones relative to rate 48.
| interval || P1 || m2 || M2 || m3 || M3 || P4 || d5 || P5 || m6 || M6 || m7 || M7
|-
| rowspan=3 | period || 48 ||  || 54 ||  ||  || 64 || 68 || 72 || 76 ||  ||  ||
|-
| 96 || 102 || 108 || 114 ||  || 128 || 136 || 144 || 152 || 162 ||  ||
|-
| 192 || 204 || 216 || 228 || 242 || 256 || 272 || 288 || 304 || 322 || 342 || 362
|}
All of these are within 6 cents of an exact number of semitones relative to period 48.


Better would be to have the user specify the actual divider, for numbers from 2 to 512. Numbers less than 50 may have a reason to be missing from the current table, so maybe some workaround (prohibition or offset) would be warranted. the IRQ and Loop flags would have to be moved for this behavior, though.
Better would be to have the user specify the actual divider, for numbers from 2 to 512. Numbers less than 50 may have a reason to be missing from the current table, so maybe some workaround (prohibition or offset) would be warranted. the IRQ and Loop flags would have to be moved for this behavior, though.

Revision as of 05:44, 18 October 2014

How to read the tables:

Pick the table for your system. Find the rate (written to $4010) on the top or side. Numbers inside are measured in cents of detuning relative to the other rate. Red and blue indicate rates that will sound noticeably flat or sharp, using a Just-noticeable difference of 6 cents. Numbers in green specify the number of other rates that are in tune with the one selected.

kHz 33.14 24.86 21.31 16.88 13.98 12.60 11.19 9.42 8.36 7.92 7.05 6.26 5.59 5.26 4.71 4.18
NTSC $F $E $D $C $B $A $9 $8 $7 $6 $5 $4 $3 $2 $1 $0
$0 16.1 14.1 -19.0 -16.3 10.2 -10.1 -3.4 -5.9 0.0 -5.5 -3.3 2.1 -3.4 1.5 -5.9 9
$1 22.0 20.1 -13.0 -10.3 16.2 -4.1 2.5 0.0 5.9 0.4 2.6 8.0 2.5 7.4 8
$2 14.6 12.6 -20.5 -17.8 8.7 -11.6 -5.0 -7.4 -1.5 -7.1 -4.8 0.6 -5.0 6
$3 19.6 17.6 -15.5 -12.8 13.7 -6.6 0.0 -2.5 3.4 -2.1 0.1 5.5 9
$4 14.0 12.1 -21.1 -18.3 8.2 -12.1 -5.5 -8.0 -2.1 -7.6 -5.4 6
$5 19.4 17.5 -15.6 -12.9 13.6 -6.7 -0.1 -2.6 3.3 -2.2 9
$6 21.7 19.7 -13.4 -10.7 15.8 -4.5 2.1 -0.4 5.5 8
$7 16.1 14.1 -19.0 -16.3 10.2 -10.1 -3.4 -5.9 9
$8 22.0 20.1 -13.0 -10.3 16.2 -4.1 2.5 8
$9 19.6 17.6 -15.5 -12.8 13.7 -6.6 9
$A 26.2 24.2 -8.9 -6.2 20.3 3
$B 5.9 3.9 -29.2 -26.5 2
$C 32.4 30.4 -2.7 1
$D 35.1 33.1 1
$E 2.0 2
$F 2
kHz 33.25 25.19 21.32 16.97 14.09 12.60 11.23 9.45 8.40 7.92 7.04 6.02 5.58 5.26 4.70 4.18
PAL $F $E $D $C $B $A $9 $8 $7 $6 $5 $4 $3 $2 $1 $0
$0 8.7 -10.7 -21.5 -26.3 -4.8 -10.7 -12.6 -12.6 -8.7 -6.9 -4.8 -33.7 -0.9 0.6 -2.8 5
$1 11.5 -7.9 -18.6 -23.5 -2.0 -7.9 -9.8 -9.8 -5.9 -4.0 -2.0 -30.9 1.9 3.4 7
$2 8.1 -11.3 -22.1 -26.9 -5.4 -11.3 -13.2 -13.2 -9.3 -7.4 -5.4 -34.3 -1.5 5
$3 9.6 -9.7 -20.5 -25.4 -3.8 -9.7 -11.7 -11.7 -7.8 -5.9 -3.8 -32.8 6
$4 42.4 23.0 12.3 7.4 28.9 23.0 21.1 21.1 25.0 26.9 28.9 0
$5 13.5 -5.9 -16.7 -21.5 0.0 -5.9 -7.8 -7.9 -3.9 -2.1 9
$6 15.5 -3.8 -14.6 -19.4 2.1 -3.8 -5.8 -5.8 -1.9 9
$7 17.4 -2.0 -12.7 -17.6 3.9 -2.0 -3.9 -3.9 8
$8 21.3 2.0 -8.8 -13.7 7.9 2.0 0.0 5
$9 21.3 1.9 -8.9 -13.7 7.8 1.9 5
$A 19.4 0.0 -10.8 -15.6 5.9 7
$B 13.5 -5.9 -16.7 -21.5 9
$C 35.0 15.6 4.8 1
$D 30.1 10.8 1
$E 19.4 7
$F 0


In a fictional alternate universe, where the DPCM period tables had been chosen to maximize in-tune choices, perhaps the periods would have instead been some subset of the following rates:

interval P1 m2 M2 m3 M3 P4 d5 P5 m6 M6 m7 M7
period 48 54 64 68 72 76
96 102 108 114 128 136 144 152 162
192 204 216 228 242 256 272 288 304 322 342 362

All of these are within 6 cents of an exact number of semitones relative to period 48.

Better would be to have the user specify the actual divider, for numbers from 2 to 512. Numbers less than 50 may have a reason to be missing from the current table, so maybe some workaround (prohibition or offset) would be warranted. the IRQ and Loop flags would have to be moved for this behavior, though.