Arkanoid controller
The Arkanoid Vaus controller was included with the Arkanoid game, and is only used for this game. It has an analog potentiometer dial and a single button.
Under the black rubber dot is another potentiometer to adjust the dial range.
The controller uses D3 and D4 so it will not work in a Four score.
Input ($4016 write)
7 bit 0 ---- ---- xxxx xxxS | +- Dial shift register strobe
Writing 1 to this bit will record the state of the dial. Writing 0 afterwards will allow the dial to be read back.
The analog to digital conversion takes time so strobing too fast will return bad dial data. A function that reads the controller multiple times in a row to avoid DPCM glitches may not work.
Output ($4016/$4017 read)
7 bit 0 ---- ---- xxxD Bxxx | | | +---- Button +------ Serial dial data
Button status is returned in D3, and does not need to be latched. Button is 1 if pressed, 0 if not pressed.
Dial data is returned in D4, MSB first. The data is also inverted. The whole dial range is about 270 degrees, and returned in $A0 steps. Variations in the analog to digital and pot physical range can vary the result slightly.
With the trim pot at minimum the range returned is $0D-$AD.
With the trim pot at maximum the range returned is $5C-$FC.
The Arkanoid game expects the range to be $54-$F4.